8455新葡萄娱集团am

8455新葡萄娱集团am

8455新葡萄娱集团am
8455新葡萄娱集团am

产品类别

联系方式

电话:0755-26738591

传真:0755-26998440

网址:

邮箱:sales@octsources.com

地址:深圳市南山区虹步路39号大习科创大厦5F

产品类别 > 隔离器/转换器 > CTU-4837电流传感器

CTU-4837电流传感器

所属品牌:美国 OSI 来源:深圳市现代豪方仪器仪表点击:530次发布时间:2021-09-02

CTU-4837电流传感器


品牌:美国 OSI

 

型号:CTU-4837

 

类型:电流传感器(磁通门闭环)

 

 


产品描述DESCRIPTION

CTU-4837型是一种闭环fl-uxgate电流传感器。2FLUxGate原理用于检测由导体中的电流fl产生的磁场强度和方向。信号调节提供与测量电流的振幅和方向成比例的输出。

The model CTU-4837 is a closed-loop fl uxgate current transducer. The 2 core fl uxgate principal is used to detect the strength and direction of the magnetic fl ux created by current fl owing in a conductor. Signal conditioning provides an output proportional to both the amplitude and direction of the measured current.







参数

电流输入

0-0.4Aac

电压输入

-15Vdc

输出

0-±5Vd

准确度

<0-25mA

频率

直流->18KHz

 

 

 





输入INPUT

电流

范围

0-±0.4Adc

超量程(带比例输出)

±0.8Adc

超出范围(无损坏)

±40Adc

输出OUTPUT

类型

±5.0Vdc

缩放比例

-0.4/0/+0.4Adc输入=-5/0/+5Vdc输出

载入

10KΩ

输入90%的响应时间

20ms

频带宽度(-3db

直流至>18kHz

介电测试DIELECTRIC TEST

导体通过窗口输出

3500Vdc

精确性ACCURACY

设定值、线性和重复性

<±25mV

电偏移

<±75mV

零点偏移

I=±0.4Adc Vos=±2mV

I=±40Adc Vos=±20mV

交流纹波

<13mVac

相对于中心读数的位置(窗口)灵敏度

±3mV

仪表功率INSTRUMENT POWER

电压

±15Vdc±5%(最大16.5Vdc

电流

45mAdc

温度TEMPERATURE

工作范围

-40 ~ 85ºC

影响

-40+85ºC

1.0mV/ºC

物理性质PHYSICAL

工作湿度

0-95%不冷凝

重量

典型17

终端

印刷电路板安装引脚

冲击与振动

TBD









连接和外壳尺寸


























安装/操作/保修/INSTALLATION / OPERATION / WARRANTY

 

安装说明/INSTALLATION INSTRUCTIONS

1.只能由合格的电工进行安装!

2.在进行任何电气连接之前,确保电气服务已断开。

3.支路保护按国家和地方规范要求设置检查机构的报告。

4.按要求布线,并按照本表和装置上的接线图固定到端子上。

5.传感器适合安装在600Vac线路上。

6.为防止与带电电路接触,当安装在裸母线上时,要求传感器安装在需要使用工具进入的外壳中。当安装在绝缘电缆上时不需要第二个外壳的电缆。

1. Installation should be performed by qualifi ed electricians only!

2. Make sure electrical service is disconnected before making any electrical connections.

3. Branch circuit protection is required to be provided in accordance with the National and Local codes of the inspection authority.

4. Route wires as required and secure to terminals per connection diagram on this sheet and on the unit.

5. Transducers are suitable for installation on 600Vac lines.

6. To prevent contact with live circuits, when installed on a bare bus bar, the transducer is required to be mounted in an enclosure that requires the use of a tool for access. When installed on an insulated cable this second enclosure is not required.

 

 

操作说明/OPERATING INSTRUCTIONS

1.本装置适用于海拔2000米以下的室内使用。

2.根据安装类别(过电压)II,污染等级2的瞬态过电压。

3.如果需要清洁外表面,则应断电所有供应服务(两个测量和仪表电源电路),并用软刷刷洗或用低压空气吹扫。使用适当的眼部保护。不适合清洗软管。

4.最高相对湿度80%,温度最高31ºC,线性下降至50% 40℃时的相对湿度。

5.最大工作温度范围为-20°C60°C

1. This unit is intended for indoor use at altitudes up to 2000 meters.

2. Transient overvoltages according to Installation Category (overvoltage) II, Pollution Degree 2.

3. If cleaning of the exterior surface is necessary, de-energize all services of supply (both measuring and instrument power circuits) and brush with a soft brush or blow off with low-pressure air. Use appropriate eye protection. Not suitable for hose-down cleaning.

4. Maximum relative humidity 80 percent for temperatures up to 31ºC decreasing linearly to 50 percent relative humidity at 40ºC.

5. Maximum operating temperature range is -20°C to 60°C.